Section 6 − programs, 1. overview of programs, 2. individual program information – Miller Electric 460Volt User Manual

Page 31

Advertising
background image

OM-188 304 Page 27

SECTION 6 − PROGRAMS

.

Synergic Information: The manufacturer makes no warranties, express or implied, that welds made using the synergic parameters of this equip-

ment will meet the requirements of the application.

The synergic parameters contained in this equipment are intended only to be a general guideline. The choice and use of any synergic setting must

be tested as to its suitability for the application.

6-1. Overview Of Programs

Program #

Wire Type

Wire Size

Shielding Gas

IPM: Min

IPM: Max

1

Steel

.035 in

Argon/CO

2

100

780

2

Steel

.045 in

Argon/CO

2

80

550

3

Stainless

.035 in

98% Argon/2% CO

2

100

780

4

Stainless

.045 in

98% Argon/2% CO

2

90

620

5

4043AL

.035 in

Argon

140

870

6

4043AL

.047 in

Argon

100

730

7

5356AL

.035 in

Argon

180

880

8

5356AL

.047 in

Argon

140

730

9

Nickel

.035 in

75% Argon/25% Helium

80

780

10

Silicon Bronze

.035 in

Argon

120

780

11

Metal Core

.045 in

Argon/CO

2

100

550

12

Metal Core

.052 in

Argon/CO

2

60

450

6-2. Individual Program Information

Program 1 −− .035 ER70S−3 Mild Steel −− Recommended Gases: Argon/CO

2

Gas: Argon/CO

2

mixes up to 10% CO

2

;

Argon/O

2

mixes up to 5% O

2

IPM

Trim

Peak Amp

Background Amp

Freq.

Pulse Width

Starting Amps

100

0

288

43

49

1.55

451

168

10

304

54

93

1.61

491

236

20

332

67

110

1.73

501

304

30

353

80

124

1.86

529

372

40

360

84

155

1.96

529

440

50

375

88

180

2.05

529

508

60

385

98

195

2.13

529

576

70

390

101

208

2.21

529

644

80

345

109

215

2.30

529

712

90

398

114

240

2.38

529

780

100

400

121

260

2.48

529

Advertising
This manual is related to the following products: