Maytag MDG30MNV User Manual

Page 17

Advertising
background image

113307 - 7

Maytag Co.

13

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT:

NOTES: A.

B.

208 VAC AND 240 VAC ARE NOT THE SAME. When ordering,
specify
exact voltage.

When fuses are used they must be dual element, time delay, current

limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse

value, by applying either local and/or National Electrical Codes to

listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type
ONLY. For others, calculate/verify correct breaker size according to
appliance amp draw rating and type of breaker used.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

CIRCUIT

BREAKER

60 Hz

50 Hz

120

2

8.7

4.6

15

2. Electrical Service Specifications

6/25/08

3. Grounding

A ground (earth) connection must be provided and installed in accordance with state and local codes. In
the absence of these codes, grounding must conform to applicable requirements of the National Electrical
Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the installation must conform to applicable
Canada Standards: Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION. The
ground connection may be to a proven earth ground at the location service panel.

For added personal safety, when possible, it is suggested that a separate ground wire be connected from the
ground connection of the dryer to a grounded cold water pipe. DO NOT ground to a gas pipe or hot
water pipe
. The grounded cold water pipe must have metal-to-metal connection ALL the way to the
electrical ground. If there are any nonmetallic interruptions, such as, a meter, pump, plastic, rubber, or other
insulating connectors, they must be jumped out with no. 4 copper wire and securely clamped to bare metal
at both ends.

IMPORTANT: For personal safety and proper operation, the dryer must be grounded.

Provisions are made for ground connection in each dryer at the electrical service connection area.

4. Electrical Connections

A wiring diagram is located inside the control box for connection data.

If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord/pigtail
(wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker
panel. In both cases, a strain relief must be installed where the wiring enters the dryer.

IMPORTANT: A separate protected circuit must be provided to each dryer.

Advertising
This manual is related to the following products: