WARNING: If the water in the supply line or water solenoid valve freezes, the fire suppression system

will be INOPERATIVE!!

Typical Water Supply

OPTIONAL MANUAL BYPASS

Provisions are made in the dryer’s fire suppression system for the installation of an optional manual bypass. The
connections for the manual bypass are made at the “T” or “three way” fitting located in the outlet supply side of
the water solenoid valve. The use and connections of this manual bypass are at the option or discretion of the
owner.

The water connection for the manual bypass is made to the “T” or “three way” fitting which has a 3/8” F.P.T.
and a coupling must be used to provide the minimum 1/2” supply (feed) line.

If the rear area of the dryer or the water supply is located in an area where it will be exposed to cold/freezing
temperatures, provisions must be made to protect these water lines from freezing.