Compensator Operation
3 Product Description
20 User Manual RKP-II (CA53461-001; Version 2, January 2010) © 2010 Moog GmbH
3.5.5 Load Sensing Compensator with p-T Control
Notch, R1
Load Sensing
Compensator with p-T
Control Notch, R1
Metering orifice:
Manually remote adjustable orifice valve or proportional orifice valve.
Pressure pilot valve:
Manually remote adjustable proportional pressure valve Q = 1–1.5 l/min.
For multiple pumps feeding in one common line, only one compensator with a
p-T control notch may be used. This compensator must be set to the higher
Δp
value.
Fig. 9: Load Sensing Compensator with p-T Control Notch, R1
Pos.
Description
Pos.
Description
1
Metering orifice for flow control
8
Δp spring
2
Safety valve p = p
max.
+ 30 bar
9
Locked adjustment screw
3
Control piston 2
10
Orifice Ø 0.8 ... 0.9mm
4
Control piston 1
11
Locknut for the adjustment screw
5
Adjustment of zero stroke
12
Set at pilot valve
6
Pilot pressure valve:
13
Set at metering throttle
7
Valve spool