2 installing the pump – Moog RKP-II User Manual

Page 42

Advertising
background image

Installing the Pump

6 Mounting

34 User Manual RKP-II (CA53461-001; Version 2, January 2010) © 2010 Moog GmbH

6.2 Installing the Pump

Installing the Pump

Pre-Conditions:

• Mounting area is freely accessible.

• Machine / equipment is at zero pressure and idle.

• Operation fluid matches the information on the order data sheet.

• Standard tools and mounting material are at hand.

• Supplementary documentation is available.

• The specified rotation of the pump corresponds with the drive motor.

WARNING

Risk of Crushing!
During mounting, the pump may topple over and crush body
parts.

• Select lifting tackle to correspond with the overall weight

of the pump.

• Attach the lifting tackle to the pump properly.

Ö Chap. "5.2 Transporting the Pump", Page 29

• Avoid all areas below the floating load.

WARNING

Risk of injury and poisoning by dangerous operating fluid!
Leaks from dangerous operating fluid may lead to serious
injuries.

• Check to ensure that the operating fluid in use does not

pose a risk.

• Make sure that the machine / equipment is at zero

pressure and idle.

• Wear protective work equipment such as, e. g., work

gloves.

Ö Chap. "2.2.4 Work Safety", Page 9

DANGER

Risk of Death by Electrocution!
Contact with hot parts may lead to severe injuries and even
death.

• Make sure that the machine / equipment is idle.

CAUTION

Damage to Property from Soiling!
Removing end caps to the pump connections may lead to
soiling and as a result property damage.

• Do not remove end caps until shortly before mounting.

WARNING

Risk of injury and property damage as a result of
vibration!
Vibrations from machines / equipment parts may lead to bodily
injury or property damage.

• Uncouple the pump using suitable antivibration elements.

The pump's mounting position is optional.