6 Mounting

Electrically connecting the pump

© 2010 Moog GmbH User Manual RKP-II (CA53461-001; Version 2, January 2010) 37

6.5 Electrically connecting the pump

Electrically connecting the
pump

6.6 Arranging Multiple Pumps

6.6.1 Determining the through drive torque

Arranging Multiple
Pumps, Determining the
through drive torque

Additional pump stages can be mounted axially to the pump and as a result, all
pumps can be driven by the same shaft. Available for multiple mounting
purposes are radial piston pumps (the maximum size to be selected should be
equal to pump stage 1) or other pumps with adapter flanges for SAE-A, SAE-B
or SAE-C. For the maximum permissible through drive torque of the added
pumps, see the table below.

Ö Tab. 7, Page 37

Through Drive Torque for Added RKP, SAE-A, SAE-B or SAE-C Adapters

The required through drive torque to drive the added on pumps should be
determined by using the following variables:

Through Drive Torque of Pump Stage 1 to 2:

Formula for Through Drive
Torque for Multiple Pumps

Example:

Based on a pump combination
RKP 63 + RKP 63 + RKP 32 + AZP 16
280 bar, 210 bar, 150 bar, 50 bar
this would mean:

The pump's electrical is connected through the control unit:
Ö Application Instruction RKP-D with CAN Bus Interface

Pump Stage 1

Pump Stage 2

RKP-II

RKP-II

SAE-A

SAE-B

SAE-C

Size [cm

3

/R]

19

32
45

63
80

100

140

19

90 Nm

90 Nm

32/45

185 Nm

185 Nm

110 Nm

185 Nm

63/80/100

400 Nm

400 Nm

400 Nm

110 Nm

280 Nm

400 Nm

140

400 Nm

400 Nm

400 Nm

620 Nm

110 Nm

280 Nm

620 Nm

Tab. 7: Permissible Through Drive Torques

V [cm

3

/R]

: Displacement

p [bar]

: Pressure

[%]

: Hydro-mechanical efficiency

M [Nm]

: Through drive torque

η

hm

M

1

1 59

,

V

i

p

i

η

hm

i

-----------------

i

2

=

n

=