7 Operation
Initial Pump Set-Up
© 2010 Moog GmbH User Manual RKP-II (CA53461-001; Version 2, January 2010) 47
7.1.2.4 Servo Control, C1
Fig. 25: Servo Control, C1
Procedure:
1. Regulate the pump's flow volume by positioning the adjustment lever.
Information about the Servo Control:
Ö Chap. "3.5.7 Servo Control, C1", Page 22
The zero position and the end position are set at the factory. Manual or
mechanical operations are performed using the adjustment lever.
Pos.
Description
1
Zero position (set at the factory)
2
End position / ±V
max.
(set at the factory)
Displacement V [cm
3
/R]
19
32
45
63
80
100
Angle
α [°]
44
47
57
44
56
56
Control torque M [Nm]
Zero position
1.2
1.6
End position
1.6
1.7
2.4
2.6
2.6
max.
8
Tab. 11: Adjustment Torque Servo Control