Moog RKP-II User Manual
Page 53

7 Operation
Initial Pump Set-Up
© 2010 Moog GmbH User Manual RKP-II (CA53461-001; Version 2, January 2010) 45
7.1.2.1 Hydraulically Driven Remote Pressure
Compensator, H1
Default Compensator Settings
Δp = 10 bar + 2 bar or Δp = 20 bar + 2 bar
Hose for Control Line
The following information are recommended values:
Hose length approx. 800 mm
7.1.2.2 Load Sensing Compensator with p-T Control
Notch, R1
Default Compensator Settings
RKP-II 16–100:
Δp = 10 bar + 2 bar
RKP-II 140:
Δp = 13 bar + 2 bar
Hose for Control Line
The following information provides recommended values:
Hose length approx. 800 mm
Information on the compensator:
Ö Chap. "3.5.2 Hydraulically Driven Remote Pressure Compensator, H1",
Page 17
The information in this section also applies to:
Ö Chap. "3.5.4 Load Sens-
ing Compensator, J1", Page 19
When high dynamics are required for flow control, orifice and control flow
volume, contact us to discuss application specific compensator
adjustments.
Pump Type
NW [mm]
RKP-II 19
6
RKP-II 32, 45
8
RKP-II 63, 80, 100
10
Tab. 8: Nominal width for Control Line Hose
Information on the compensator:
Ö Chap. "3.5.5 Load Sensing Compensator with p-T Control Notch, R1",
Page 20
Pump Type
NW [mm]
D1 [mm]
D2 [mm]
RKP-II 19, 32, 45
6
0.9
1.2
RKP-II 63, 80, 100
8
0.9
1.2
RKP-II 140
8
0.8
1.1
Tab. 9: Nominal width for Control Line Hose