Initial Pump Set-Up

7 Operation

48 User Manual RKP-II (CA53461-001; Version 2, January 2010) © 2010 Moog GmbH

7.1.2.5 Power Control, S1, S2

Fig. 26: Power Control, S1, S2

Default Compensator Settings

Δp = 10 bar + 2 bar

Hose for Control Line

The following information provides recommended values:

Hose length approx. 800 mm

Information on the power control:
Ö Chap. "3.5.8 Power Control, S1", Page 23
Ö Chap. "3.5.9 Power Control, S2", Page 25

The power control settings are set at the factory and may not be
changed!

Pos.

Description

1

Power control setting (set at the factory; may not be changed)

2

Pressure decrease (set at the factory

Δp = 10 bar + 2 bar)

3

Control port G 1/4"

Pump Type

NW [mm]

RKP-II 19

6

RKP-II 32, 45

8

RKP-II 63, 80, 100

10

Tab. 12: Nominal width for Control Line Hose