Initial Pump Set-Up
7 Operation
48 User Manual RKP-II (CA53461-001; Version 2, January 2010) © 2010 Moog GmbH
7.1.2.5 Power Control, S1, S2
Fig. 26: Power Control, S1, S2
Default Compensator Settings
Δp = 10 bar + 2 bar
Hose for Control Line
The following information provides recommended values:
Hose length approx. 800 mm
Information on the power control:
Ö Chap. "3.5.8 Power Control, S1", Page 23
Ö Chap. "3.5.9 Power Control, S2", Page 25
The power control settings are set at the factory and may not be
changed!
Pos.
Description
1
Power control setting (set at the factory; may not be changed)
2
Pressure decrease (set at the factory
Δp = 10 bar + 2 bar)
3
Control port G 1/4"
Pump Type
NW [mm]
RKP-II 19
6
RKP-II 32, 45
8
RKP-II 63, 80, 100
10
Tab. 12: Nominal width for Control Line Hose