2 attaching the adapter flange – Moog RKP-II User Manual
Page 48

Arranging Multiple Pumps
6 Mounting
40 User Manual RKP-II (CA53461-001; Version 2, January 2010) © 2010 Moog GmbH
6.6.2 Attaching the Adapter Flange
Pre-Conditions:
Attaching the Adapter
Flange
• The centering diameters of both the adapter flange and the add-on pump
match.
• The dimensions of the through drive shaft match with the add-on pump.
• The flange diameters of both the adapter flange and the add-on pump
match.
• The connection surfaces are clean.
Procedure:
1. Attach the adapter flange to the add-on pump without damaging the
O-rings.
2. Bolt the adapter flange to the pump:
- Observe the tightening torques of the fasteners.
Ö Chap. "12.2 Tightening Torque", Page 63
For adding on a pump, the following adapter flanges are available:
Adapter flange SAE-A with 9-tooth shaft
Fig. 22: Adapter flange SAE-A with 9-tooth shaft
The adapter includes through drive shaft, seals (HNBR), intermediate ring for
RKP 63–140 and two fastening screws.
Profile
Thread
Shaft end
Thread
for add-on pump
Bolt
Flange Code:
82-2
Shaft Code:
16-4
Spline as per:
ANSI B92.1 9T 16/32 DP Flat root side fit
Conditions for
attachment:
RKP with heavy-duty through drive