2. symbols and definitions, Section 4 − introduction, 1. specifications – Miller Electric PipePro Dual User Manual
Page 16
OM-230 009 Page 12
3-2. Symbols And Definitions
.
Some symbols are found only on CE products.
A
Amperes
V
Volts
Alternating Current
X
Duty Cycle
IP
Degree Of
Protection
Hz
Hertz
Program
Wire Feed
Jog
Output
Trigger
Line Connection
Set Up
Sequence
Trigger Hold On
Trigger Hold Off
Purge
Press To Set
Start
Crater
Time
Preflow Time
Postflow Time
Read Instructions
Increase
I
1
Primary Current
I
2
Rated Current
U
2
Load Voltage
U
1
Primary Voltage
A
B
Dual Schedule
SECTION 4 − INTRODUCTION
4-1. Specifications
Type of Input
Power
Welding Power
Source Type
Wire Feed Speed
Range
Wire Diameter
Range
Welding
Circuit
Rating
IP
Rating
Overall
Dimensions
Weight
40 Volts DC
10 Amperes
PipePro 450 RFC with
14-Pin And Contactor
Control
50 To 780 ipm
(1.3 To 19.8 mpm)
.023 To 1/8 in
(0.6 To 3.2 mm)
Max Spool
Weight: 60 lb
(27 kg)
100 Volts,
750
Amperes,
100% Duty
Cycle
IP 21
Length: 35 in
(889 mm)
Width: 12-1/2 in
(318 mm)
Height: 14 in
(356 mm)
87 lb
(39.5 kg)