OM-230 009 Page 23

6-6. Program Push Button

1

3

Program

2

1

Program Display

The number of the active program

is displayed.
2

Program Push Button

Press button to activate program

select feature. To change the pro-

gram number, press the Program

push button and rotate the Adjust

control.
3

Program Push Button LED

The LED lights to indicate the Pro-

gram push button is active.

6-7. Upper Display

5

2

V/Trim

Time (sec)

1

4

3

1

Upper Display

The upper display shows voltage/trim or time.

The unit displays both preset and actual arc

voltage. When the unit is in a welding state, ac-

tual arc voltage is displayed. The upper dis-

play shows welding sequence time when the

Time LED is illuminated.
2

Upper Display Push Button

Press and hold button to adjust or display weld

time. Release button to display voltage/trim.
3

Upper Display Push Button LED

The upper display push button LED illumi-

nates to indicate that information displayed

can be changed by the Adjust control.
4

Volts/Trim LED

5

Time LED

The LEDs below the display illuminate to indi-

cate which value is being shown.

At any time while welding, the unit permits the

adjustment of the weld sequence voltage/trim

while continuing to display actual arc voltage.

If the unit is displaying a welding sequence

that can be timed, the welding time display

mode is entered by pressing the upper dis-

play push button repeatedly until welding

time is the active parameter in the upper dis-

play. At idle, the upper display toggles be-

tween showing weld voltage/trim or weld

time, with subsequent presses of the upper

display push button.

The unit defaults to displaying welding volt-

age/trim when a welding sequence display

mode is first entered.

If the weld sequence has a time set (as in

spot time) and the trigger is held, after the

weld program is completed, ERR TRG 1 will

be displayed to indicate the weld program is

complete. Release trigger to clear error.

Advertising