12. auxiliary menus – Miller Electric PipePro Dual User Manual

Page 30

Advertising
background image

OM-230 009 Page 26

6-12. Auxiliary Menus

Program

Start
Crater
Pre/Postflow

Trigger Hold

Adjust

V/Trim

Time (sec)

Wire Speed

Amps

Sequence

Setup

Dual Schedule

3

4

2

9

8

1

5

7

6

1

Program Display

2

Program Push Button

3

Sequence Push Button

4

Upper Display

5

Upper Display Push Button

6

Lower Display

7

Lower Display Push Button

8

Adjust Control

9

Setup Push Button

Reset To Factory Settings
A reset menu is displayed if the following

four push buttons are pressed simulta-

neously: Program, Sequence, upper dis-

play, and Setup. The upper display indi-

cates “WIPE” . The lower display indicates

“OFF”. The lower push button is active indi-

cating that the Adjust control can be used to

change the unit to “WIPE ON”. When “WIPE

ON” is set, if the original four push buttons

are simultaneously pressed a second time,

the unit will reset all settings to factory de-

fault except the arc time and arc cycle

counts. If a reset is not desired, set the dis-

play to “WIPE OFF” and simultaneously

press the Program, Sequence, upper dis-

play, and Setup push buttons to exit the re-

set menu.
Auxiliary Menu

An auxiliary menu is provided if both the

Sequence and Setup push buttons are

pressed simultaneously. The Setup push

button and sequence push button LEDS

flash when the auxiliary menu is dis-

played.

Pushing the Setup push button will step

through the menu. Pushing the sequence

push button will step through the menu in re-

verse.

.

The auxiliary menu may be exited at
any time by pressing both the Se-

quence and Setup push buttons simul-

taneously.

Run-In

The run-in modes are program specific

(i.e. each program may be set to its own

run-in mode).

The upper display indicates “RUNI”. The

lower display indicates “AUTO”, meaning

the factory set automatic run-in speed is

selected.
Pressing the lower display button allows

manual setting of the run-in wire speed.

Speed may be adjusted from 10% to

100% of weld wire speed.
Pressing the lower display button again

allows disabling of the run-in feature.

When the lower display indicates “OFF”,

run-in is disabled.
Burnback
Burnback time and voltage can be specified

when the lower display indicates “BURN”

and the upper display indicates the burn-

back time or voltage. The Adjust control is

used to set the desired burnback time or

voltage. Burnback settings are program

specific. The active program is displayed in

the Program display and can be adjusted

(see Section 6-6).
Trigger Hold Setup
Trigger hold delay time is indicated by

”HOLD” in the lower display and the hold

delay time in the upper display. The adjust

control can be used to specify a new delay

time for trigger hold. Trigger hold delay time

is the minimum amount of time the trigger

must be held for trigger hold to work when

the trigger is released (the trigger hold func-

tion must be on). For example, if a trigger

hold delay time of 2.0 seconds is defined,

the operator must hold the trigger for at least

2 seconds before releasing it in order for the

trigger hold function to work. Once the trig-

ger hold function is in effect, the wire feeder

will stay On until the trigger is pressed and

released again.

There is an additional function built in

called ”maximum trigger hold time” which

is the maximum length of time the trigger

can be held and the trigger hold function

still work when the trigger is released (the

trigger hold function must be on). The

maximum trigger hold time is set at 4.0

seconds after the trigger hold delay time.

For example, if a trigger hold delay time of

2.0 seconds is defined, and the operator

held the trigger in for more than 6.0 sec-

onds, the trigger hold function would not

be in effect and the wire feeder would stop

when the trigger is released.

Trigger Program Select
The upper display shows “TSEL”. Lower

display shows “On” or “Off”. The Adjust con-

trol is used to select either “On” or “Off”.
Trigger Program Select allows the operator

to select programs by clicking the trigger

(pulling and releasing the trigger in a maxi-

mum of 0.2 seconds). The feeder will switch

between any programs that have a mini-

mum of 0.2 seconds of preflow time set in

the weld sequence.

Any combination of programs may be

used.

If only programs 1 and 3 have a minimum

of 0.2 seconds of preflow time, clicking

the trigger will toggle between programs

1 and 3.

If only programs 1, 2, and 4 have a mini-

mum of 0.2 seconds of preflow time, click-

ing the trigger will switch from 1 to 2 to 4

to 1 to 2.

Trigger Program Select cannot be used

while welding or with Dual Schedule.

Advertising