Miller Electric PipePro Dual User Manual

Page 31

Advertising
background image

OM-230 009 Page 27

Range Locks

Range locks are indicated by “LOCK” in the

upper display for wire speed or “LOCK” in

the lower display for voltage range.

In a MIG program, the voltage range lock

ranges from +/− 0 to 10 volts.

In a pulse program, the trim range lock

ranges from +/− 0 to 100.

The wire speed range lock ranges from +/−

0 to 195 IPM.

Locks are program dependent and wire

speed locks are independent from voltage/

trim command locks (i.e. you can have a

wire speed lock with or without locking the

voltage/trim command and vice versa).

Press the Upper Display Pushbutton to se-

lect Voltage/Trim Command Range Locks.

Press the Lower Display Pushbutton to se-

lect Wire Speed Range Locks.

To set a Voltage/Trim Command Range

Lock, you must choose the type of com-

mand being locked, voltage or trim based

on the type of weld process selected at the

power source. This is done by repeatedly

pressing the Upper Display Pushbutton to

cycle between OFF, T (trim) or V (voltage),

as indicated on the Upper Display.

Use the adjust knob to set the range value.

Once any program has a lock enabled, the

remaining programs with all locks “OFF”

will not be accessible. To enable additional

programs, set the lock values for one or

more Voltage/Trim Command or Wire

Speed to appropriate ranges for each pro-

gram.
Only one of the values needs to be set to

enable the program. For example, setting a

Trim of 100 and leaving the Wire Speed at

OFF will allow the welder to adjust the Wire

Speed to full range
Wire Feed Speed Units
Wire feed speed setting indicated by “WFS”

in the upper display is set to “IPM” inches−

per−minute or ”MPM” meters−per−minute.

This setting is independent of the program

selected.
Software Revision Level

The unit displays the software version

being used by the interface PCB (PC20).

When the Setup button is pressed again,

the menu repeats.

Code
Upon leaving the auxiliary menu, the user is

asked if a password code, indicated by

“CODE” in the top display should be acti-

vated.
By default the code is “OFF” in the lower

display. The user may enter a numerical

password between 0 and 999 by turning the

Adjust control.
If a code is set, when the user re-enters the

auxiliary menu, the password code must be

selected to gain access to the auxiliary

menu. Press Setup and Sequence buttons

simultaneously to enter the auxillary menu.

A failed attempt returns the user to the weld

screen and a counter is incremented. A

counter in the program display shows the

number of incorrect attempts. The user has

five attempts to enter the correct password

code before being locked out of the auxilia-

ry menu, indicated by “LOCK” in the lower

display.
The power may be cycled to continue weld-

ing, but the user will remained locked out of

the auxiliary menu.
The counter can be reset in the weld screen

by pressing the Program, Sequence, upper

display, and Set-up push buttons simulta-

neously. Resetting the counter is indicated

by “CODE” in the upper display and “RSET”

in the lower display. Pressing the Program,

Sequence, upper display, and Set-up push

buttons simultaneously again resets the

counter to 0.
To reset the password, follow the directions

under Reset To Factory Settings at the be-

ginning of this section. Note: this will reset

all settings and programs to the factory de-

faults.

Advertising