8. lower display, 9. setup push button – Miller Electric PipePro Dual User Manual

Page 28

Advertising
background image

OM-230 009 Page 24

6-8. Lower Display

1

Lower Display

The lower display shows wire speed or

amperage.
2

Lower Display Push Button

Press button to choose between wire speed or

amperage functions.
3

Lower Display Push Button LED

The lower display push button LED illuminates

to indicate that wire feed speed can be ad-

justed with the Adjust control.
4

Wire Speed LED

5

Amps LED

The LEDs below the display illuminate to indi-

cate which value is being shown.

At idle, the wire speed for the active welding

sequence may be adjusted or the amperage

of the previous weld may be displayed.

If the unit is in a welding state that does not

involve feeding wire, such as pre−flow or

post−flow, the unit displays the weld se-

quence wire speed; otherwise, the wire

speed of the active sequence segment of the

weld program (run−in, start, weld, crater,

etc.), is displayed.

Adjusting wire speed while in a welding state

will modify the weld segment of the weld pro-

gram. Wire speed for other segments of the

weld program can only be modified via the

Sequence menu.

When the unit is displaying amperage, the

Amps LED illuminates. While in a welding

state, the actual weld current is shown.

While idle, the amperage at the end of the

previous welding state is shown.

Amperage values of less than 5 Amps are

displayed as “−−−−”.

2

Wire Speed

Amps

1

5

4

3

6-9. Setup Push Button

1

Setup Push Button

Press button to choose between trigger hold

or dual schedule functions.
2

Setup Push Button LED

3

Trigger Hold LED

4

Dual Schedule LED

When the Setup button is pressed, the Set-

up push button LED flashes and the Trigger

Hold LED flashes.

Trigger hold is a per program setting.

The flashing LED indicates that the unit is in

the trigger hold display mode. In this mode

the upper display indicates HOLD and the

lower display indicates the trigger hold sta-

tus On/Off. Use the Adjust control to change

the trigger hold status or press the lower dis-

play push button. If trigger hold is turned On,

the trigger hold LED illuminates and stays

On.

When trigger hold is On, the user must

press and hold the trigger for a predefined

amount of time (the trigger hold delay time−

see Section 6-12), then release it for the trig-

ger hold function to be active. To shut off the

weld when trigger hold is On, the user must

press and release the trigger.

If a weld time is programmed, trigger hold is

disabled.

Dual Schedule is a per program pair setting

(1,2) (3,4) (5,6) (7,8).

When the Setup button is pressed a second

time, the dual schedule LED flashes. In this

mode the upper display indicates DUAL and

the lower display indicates dual schedule

status On/Off. Use the Adjust control to

change the dual schedule status if desired.

Pressing the Setup button again exits the

Setup mode. The dual schedule LED stops

flashing to indicate the dual schedule status

is Off, or remains on if dual schedule was

enabled.

While in the Setup mode, if the trigger is acti-

vated, Setup mode is terminated.

Dual schedule and trigger select cannot be

used concurrently. See Section 6-12 for

Trigger Program Select.

Trigger Hold

Setup

Dual Schedule

1

2

3

4

Advertising