6-13. Remote-14 Receptacle Information

804 667-B

1

Remote Switch

2

Remote-14 Receptacle

If the remote switch is set to MIG,

the feeder operates normally. A re-

mote control may be left attached

while the remote switch is in the

MIG mode, as the remote has no af-

fect on the operation of the wire

feeder.
If the remote switch is set to Stick/

TIG, the feeder controls and meter

displays are disabled, allowing con-

trol from a standard remote control.

When a remote control is con-

nected to the remote-14 receptacle,

the PipePro 450 RFC will automati-

cally adjust output control in a pri-

mary/secondary configuration, but

the power source must be set for

remote operation (see the PipePro

450 RFC Owner’s Manual for infor-

mation).
In this configuration, the Amp Ad-

just control on the PipePro 450 RFC

power source becomes the prima-

ry, and sets the maximum amper-

age output of the unit. The remote

control becomes the secondary,

and provides an amperage range

adjustment of 0 to 100% of what is

set on the Amp Adjust control on the

power source.

.

When in Stick/Tig mode, re-
mote program select is still

functional from the feeder.

!

Do not connect a Stick elec-

trode holder and a MIG gun

to the same output terminal

at the same time, as both

will be live when the contac-

tor is on. An external polar-

ity reversing isolation con-

trol should be used to iso-

late the outputs.