OM-230 009 Page 25

6-10. Adjust Control

Adjust

1

1

Adjust Control

The Adjust control is used to change

various parameters.

Start
Crater
Pre/Postflow

Sequence

6-11. Sequence Push Button

.

For more information on Setting
Sequence Parameters see Section 7-1
.

The Sequence push button allows the

selection of welding sequences. Five weld-

ing sequences are available. The default

sequence is the Weld sequence. The Weld

sequence is active on power up. Three

welding sequence LEDs are located above

the Sequence push button: Start, Crater,

and Preflow/Postflow. The applicable LED

illuminates to indicate which welding se-

quence is active.

The LED illuminates to indicate that a weld-

ing sequence display mode other than Weld

is active. Welding sequences other than

Weld must be set prior to initiating the arc.

When the unit enters a welding state, all se-

quence display modes are terminated and

the weld display mode is activated.
If zero time is programmed for a timed se-

quence except for Weld, that sequence will

be skipped.

In the weld sequence display mode, the Se-

quence push button LED is Off. When the

Sequence push button is pressed, the Se-

quence push button flashes and the Start

LEDs flash. In this condition, the unit is in the

Start sequence display mode, and Start se-

quence parameters are displayed (see Sec-

tion 7-1).

When the Sequence push button is pressed

a second time, the Crater sequence LED

flashes. The Sequence push button LED re-

mains flashing. In this condition, the unit is

in the Crater sequence display mode, and

Crater sequence parameters are displayed.

When the Sequence push button is pressed

a third time, the Preflow/Postflow sequence

LED flashes. The Sequence push button

LED remains flashing. In the Preflow display

mode the upper display shows the preflow

time and the lower display indicates the ab-

breviation PRE, to inform the operator that

preflow time is displayed. If the upper dis-

play push button is pressed, the Adjust con-

trol can be used to adjust preflow.

If the lower display push button is pressed,

the Adjust control can be used to select be-

tween preflow (PRE) and postflow (POST).

When POST is selected, the upper display

can be used to specify postflow time.

When the Sequence push button is pressed

a fourth time, the unit returns to the welding

sequence display mode.

1

3

2

Welding Sequence Diagram

Preflow

Time

Start

Time

Weld

Time

Crater

Time

Postflow

Time

1

Sequence Push Button

2

Sequence Push Button LED

3

Welding Sequence LEDs