4 S-Registers

CommPlete Communications Server

47

S3

defines the carriage return character by its decimal ASCII code. The default setting is the ^M character

(decimal 13), which is the code for the E

NTER

key on most keyboards. S3 may be set for any ASCII

character.

Note

: If you change the S3

value, you must make corresponding changes in your data communications

software.

S4

Line Feed Character

Unit: Decimal
Range: 0–127
Default: 10 (^J)

S4

defines the line feed character by its decimal ASCII code. The default setting is ^J (decimal 10), which is

the code for the line feed key on most keyboards that have such a key. S4

may be set for any ASCII

character.

S5

Backspace Character

Unit: Decimal
Range: 0–127
Default: 8 (^H)

S5

defines the backspace character by its decimal ASCII code. The default setting is the ^H character

(decimal 8), which is the code for the BACKSPACE key on most keyboards. S5

may be set for any ASCII

character.

Note

: If you change the S5

value, you must make corresponding changes in your data communications

software.

S6

Wait Time for Dial Tone

Unit: 1 second
Range: 2–255 (North America), 4–255 (International), 4–7 (U.K.)
Default: 2 (North America), 4 (International and U.K.)

S6

defines the length of time the modem waits after the E

NTER

key is pressed before executing a dial

command. The default setting is two seconds for North America, four seconds elsewhere.

S7

Time for Carrier (Abort Timer)

Unit: 1 second
Range: 1–255 (USA), 1–45 (Canada and International), or 1–55 (U.K.)
Default: 45 (North America and International) or 55 (U.K.)

S7

determines the abort timer delay time, which is the amount of time your modem will wait for a carrier

signal before it disconnects. The default value is 45 seconds, except the U.K. model, for which it is 55
seconds. This means that, after dialing, the modem waits for a carrier signal for up to 45 or 55 seconds and,
if none is detected, aborts the call. The maximum S7

value is 255 seconds for the USA model, 45 seconds

for Canadian and International models, and 55 seconds for the U.K. model.

S8

Pause Time for Comma

Unit: 1 second
Range: 0–255 (North America), 4–255 (International), 4–7 (U.K.)
Default: 2 (North America), 4 (International and U.K.)