E AT Command Summary

CommPlete Communications Server

81

Command

Values

Description

&Rn

n = 0, 1, or 2

Clear to Send Control
&R0 Let CTS state follow RTS state when online.

*** &R1 Force CTS high (on).

&R2 Let CTS drop on disconnect for time set by S24,

then go high again.

&RAn

n = 0 or 1

Asymmetric Bit Rate

*** &RA0 Enable asymmetric bit rate operation.

&RA1 Disable asymmetric bit rate operation.

&RDn

n = 0 or 1

Square Wave Ring Detect
&RD0 Full wave ring detect only.

*** &RD1 Full wave and square wave ring detect.

&RFn

n = 0 or 1

CTS/RTS Interaction Control
&RF0 Let CTS follow RTS.

*** &RF1 Let CTS act independently.

&RN

n/a

Rate Renegotiation
Forces the modem to renegotiate the data rate.

&RP

n/a

Immediate Line Probe
Initiates a retrain that makes the modem read line
probe information if %DP1 is selected. Valid only
when online in V.34 mode.

&RR

n/a

Retrain
Initiates an immediate retrain without a line probe
reading.

$Rn

n = 0 or 1

Retransmit Count

*** $R0 Disconnect after 12 retransmits.

$R1 Do not disconnect after 12 retransmits.

Sr=n

r = 0–11, 13,
24, 25, 30,
32, 34, 36,
37, 43, 48, or
94; n varies

Set Register Value
Set value of S-register r to value of n, where n is
entered in decimal format.

Sr?

r = 0–11, 13,
24, 25, 30,
32, 34, 36,
37, 43, 48, or
94

Read Register Value
Read value of S-register r and display value in 3-digit
decimal form.

&Sn

n = 0, 1, or 2

Data Set Ready Control
&S0 Force DSR high (on).

*** &S1 Let DSR follow CD.

&S2 DSR drops on disconnect for time set by S24,

then goes high again.