Multi-Tech Systems MT3334HD8 User Manual

Page 54

Advertising
background image

MT3334HD8 User Guide

48

CommPlete Communications Server

S8

determines the length of the pause caused by a comma in a dialing command. The default setting is two

seconds for the North American model, and four seconds for the International and U.K. models. S8

may

be set for up to 255 seconds. S8

also defines the length of time the modem waits before retrying a call after

it detects a busy signal. Some computer systems need more than two seconds to reset, in which case you
should increase the value of S8.

S9

Carrier Detect Response Time

Unit: 100 ms
Range: 1–255
Default: 6

S9

determines the time delay between when the modem first detects a valid incoming carrier signal and

when the modem turns on its Carrier Detect circuit. The default setting is 600 milliseconds (six units of
100 ms each). S9

may be set for up to 25.5 seconds.

S10

Carrier Loss Disconnect Delay Time

Unit: 100 ms
Range: 1–254, 255
Default: 7

S10

defines the length of time after a loss of carrier signal before the modem disconnects. The default

setting is 700 ms (seven units of 100 ms each). Maximum delay is 25.4 seconds (decimal 254). Setting the
S10

value to 255 causes the modem not to disconnect with loss of carrier.

S11

Tone Dialing Spacing and Duration

Unit: 1 ms
Range: 1–255 (USA) or 80–255 (Canada, U.K., International)
Default: 70 (USA) or 80 (Canada, U.K., International)

S11

sets the speed of tone dialing (spacing and tone duration times). The default value is 70 units for

domestic models and 80 units for Canadian and International models, where each unit is one ms. In other
words, for domestic modems, each tone is sustained for 70 ms followed by a 70 ms pause. The minimum
S11

value allowed by most telephone systems is 50 ms (50 units). Very few telephone systems can handle

anything faster than that. The maximum S11 value is 255 ms (255 units).

S13

Remote Configuration Escape Character

Unit: Decimal
Range: 0–127
Default: 37 (%)

S13

defines the remote configuration escape character by its decimal ASCII code. The S13

default is the

percent character (decimal 37). When you enter the S13-defined character three consecutive times from a
remote site, your modem responds with its remote configuration procedure. A value of 0 disables remote
configuration.

S17

Changing Break Time

Unit: 10 ms
Range: 1–255
Default: 25 (250 ms)

S17

defines the break time (space) the modem sends the DTE when it receives a break signal from a remote

modem. Break duration is adjustable in 10 millisecond increments. The default is set to 25, for a 250
millisecond break.

Advertising