Multi-Tech Systems MT3334HD8 User Manual

Page 88

Advertising
background image

MT3334HD8 User Guide

82

CommPlete Communications Server

Command

Values

Description

&SFn

n = 0 or 1

DSR/CD Interaction Control

*** &SF0 Select DSR to follow CD.

&SF1 Select DSR to be independent.

$SBn

n = speed

Serial Port Baud Rate

Baud Adjust

$SB300

Select 300 bps at serial port.

($BA) must

$SB1200

Select 1200 bps at serial port.

be off.

$SB2400

Select 2400 bps at serial port.

$SB4800

Select 4800 bps at serial port.

$SB9600

Select 9600 bps at serial port.

$SB12000

Select 12,000 bps at serial port.

$SB19200

Select 19,200 bps at serial port.

$SB38400

Select 38,400 bps at serial port.

$SB57600

Select 57,600 bps at serial port.

*** $SB115200 Select 115,200 bps at serial port.

#Sy

y = password

Enter Setup Password
Password is case sensitive.

#S=y

y = password

Store Setup Password
Password must be 6–10 characters long, and may
consist of any keyboard characters.

T

In dialing
command

Tone-Dial
Modem tone-dials numbers following the T.

&Tn

n = 4 or 5

Respond to Remote Digital Loopback Signal
&T4 Enable response to remote digital loopback

signal.

*** &T5 Disable response to remote digital loopback

signal.

$Tn

n = 0 or 1

Calling Tone
$T0

Enable calling tone.

*** $T1

Disable calling tone.

#Tn

n = 0 or 1

Trellis-Coded Modulation
#T0

Disable trellis-coded modulation.

*** #T1

Enable trellis-coded modulation.

Un

n = 0–3

Loopback Test Modes
U0

Enable analog loop originate mode.

U1

Enable analog loop answer mode.

U2

Enable remote digital loopback mode.

U3

Enable local digital loopback mode.

Vn

n = 0 or 1

Result Codes (Verbose/Terse)
V0

Result codes sent as digits (terse response).

*** V1

Result codes sent as words (verbose
response).

Advertising