Warning clearances, Clearances to combustibles mantel clearances – Monessen Hearth Direct Vent Gas Fireplace KHLDV SERIES User Manual
Page 10
10
73D0024
FIREPLACE
WALL
COMBUSTIBLE
MATERIAL
AREA
6"
5"
3"
2.5"
4.5"
45°
3.5"
3.5"
1"
1.5"
1.5"
Follow these instructions carefully to ensure safe installation. Failure to follow
in struc tions exactly can create a fi re hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other
than wood fl ooring. If installed on carpet or vinyl fl ooring, the appliance shall be installed
on a metal, wood or noncombustible material panel ex tend ing full width and depth of
the appliance.
W
ARNING
CLEARANCES
CLEARANCES TO COMBUSTIBLES
MANTEL CLEARANCES
NOTE: The combustible area above the facing must not protrude more than
3
/
4
" from the facing. If it does,
it is considered a mantel and must meet the mantel requirements listed in this manual.
Figure 5 - Clearances from the mantel,
ceiling, and side wall.
Figure 5a - Mantel clearances.