Checking gas pres sure, Electrical installation, Warning – Monessen Hearth Direct Vent Gas Fireplace KHLDV SERIES User Manual

Page 25

Advertising
background image

73D0024

25

CHECKING GAS PRES SURE

AND

ELECTRICAL INSTALLATION

1. Check gas type. The gas supply must be the same as

stated on the appliance’s rating decal. If the gas supply
is different from the fireplace, STOP! Do not install
the appliance. Contact your dealer immediately.

2. To ease installation, a 24" (mm) flex line with manual

shut-off valve has been provided with on this appli-
ance. Install and attach

3

/

8

" gas line onto shut-off

valve.

3. After completing gas line connection, purge air from

gas line and test all gas joints from the gas meter to
the fireplace for leaks. Use a solution of 50/50 water
and soap solution or a gas sniffer.

4. To adjust flame height, turn HI/LO knob to HI to get

maximum pressure to burner. Turn HI/LO knob to
LO to get minimum pressure. NOTE: To make the
process of checking the gas pressure easier, unfasten
the two screws which secure the gas valve to the side
of the firebox and bring forward. [Remove the glass
to allow the valve to come forward. (See page 29 for
glass removal.)] When done, you must refasten the gas
valve into place.

5. To check gas pressures at valve, turn captured screw

counter clockwise 2 or 3 turns and then place tubing to
pressure gauge over test point. Turn unit to high. See
Figure 25.
After taking pressure reading, be sure and
turn captured screw clockwise firmly to reseal. Do not
over torque. Check test points for gas leaks.

Do not use open fl ame to check for
gas leaks.

W

ARNING

Figure 25 - Gas Pressure Check at Gas Valve

Pressure

Test “IN”

Pressure

Test “OUT”

HI/LO

Knob

Pilot Adjustment

Screw

ELECTRICAL WIRING

This fireplace will work without any electrical supply. Electricity is only needed to operate the blower and the light located
behind the logs inside the firebox.

NOTE: If installed in mobile home, fi replace must be bolted securely to fl oor.

Electrical connections should only be performed by a qualifi ed, licensed electrician.
Main power must be off when connecting to main electrical power supply or performing
service. All wiring shall be in compliance with all local, city, and state codes. The
appliance, when installed, must be electrically grounded in accordance with local codes,
or in the absence of local codes, with the National Electrical Code ANSI/ NFPA 70 (latest
edition)
and Canadian Electrical Code, CSA C22.1.

W

ARNING

Label all wires before disconnecting when servicing controls. Wiring errors can cause
improper and dangerous operation.

CAUTION

Verify proper operation after servicing.