73D0024

PRE-INSTALLATION INFORMATION

INSTALLING ABOVE 2000 FEET

• In the USA, the appliance must be derated 4% for every 1,000 ft above 2,000 ft elevations. Where the heating value of

the gas has been reduced, these rules do not apply.

• In Canada, these appliances are certified for altitudes of 0 – 2000 ft, and must be de-rated by 10 percent for installations

between 2000 and 4,500 ft. (derate an additional 4% for every 1,000 ft. above 4,500 ft. elevations).

ORIFICE SIZES, PRESSURES AND BTUs

NATURAL GAS

PROPANE GAS

Manifold Press: (W.C.)

3.5"

Manifold Press: (W.C.)

10"

Maximum Supply Pressure

10.5"

Maximum Supply Pressure

13"

Minimum Supply Pressure

4.5"

Minimum Supply Pressure

11"

BEFORE YOU START

Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and
immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts.
Check your packing list to verify that all listed parts have been received. You should have the following:
• Fireplace (Firebox and Burner System)
• Rock

Wool

• Log

Set

ITEMS REQUIRED FOR INSTALLATION

Tools: Building

Supplies:

• Phillips Screwdriver

• Framing materials

• Hammer

• Wall finishing materials

• Saw and/or saber saw

• Non-combustible finishing material or dura-rock*

• Pipe Wrench

• Caulking material (non-combustible)

• Level

• Fireplace surround material (non-combustible)

• Measuring Tape

• Piping complying with local codes

• Electric Drill and Bits

• Tee joint

• Pliers

• Pipe sealant approved for use with propane/LPG

• Square

(resistant to sulfur compounds)

* Only used if desired to cover painted face other than using tiles or marble. If tiles or marble are used around the face then
the non-combustible material is not needed.

Model Number

KHLDV400

KHLDV500

Gas Type

Natural

Propane

Natural

Propane

Max. Btu/hr Input

40,000

40,000

50,000

50,000

Min. Btu/hr Input

28,500

30,500

35,500

38,500

Rear Orifi ce Size

#35 (.110")

#52 (.0635")

#30 (.1285")

#50 (.070")

Front Orifi ce Size

#49 (.073")

#56 (.0465")