Vent installation – Monessen Hearth Direct Vent Gas Fireplace KHLDV SERIES User Manual

Page 16

Advertising
background image

16

73D0024

V

G

G=6" (152mm)

F

F=6" (152mm)

V

V

G

G = Combustible 24"(610mm)

Noncombustible 18"(457mm)

Combustible &
Noncombustible
H = 24" (610mm)
J = 20" (508mm)

V

H

J

C = Maximum depth of 48" (1219mm)

for alcove location

D = Minimum width for back wall of

alcove location
Combustible - 38" (965mm)
Noncombustible - 24" (610mm)

E = Clearance from corner in alcove

location
Combustible - 6" (152mm)
Noncombustible - 2" (51mm)

E

V

D

C

C

Inside Corner

Alcove Location

Outside Corner

Balcony with No Side Wall

Balcony with Perpendicular

Side Wall

40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10

8
6
4
2

2 4 6 8 10 1214 16 1820

eg: A

VENT INSTALLATION

TERMINATION CLEARANCES FOR BUILDINGS WITH COMBUSTIBLE
AND NONCOMBUSTIBLE EXTERIORS

Figure 9 - Allowable Venting Chart

HOW TO USE THE VENT GRAPH

The Vent Graph should be read in conjunction with the following
vent installation instructions to determine the relationship between
the vertical and horizontal dimensions of the vent system.
1. Determine the height of the center of the horizontal vent pipe

exiting through the outer wall. Using this dimension on the
Sidewall Vent Graph below, locate the point intersecting with
the slanted graph line.

2. From the point of this intersection, draw a vertical line to the

bottom of the graph.

3. Select the indicated dimension, and position the fireplace in

accordance with same.

Example: If the vertical dimension from the fl oor of the
fi replace is 11' (3.4m) the horizontal run to the face of the
outer wall must not exceed 14' (4.3m).

Example: If the vertical dimension from the fl oor of the unit
is 7’ (2.14m), the horizontal run to the face of the outer
wall must not exceed 8

1

/

2

' (2.6m).

Sidewall Vent Graph showing the relationship between vertical and
horizontal dimensions for a Direct Vent flue system.

Figure 10 - Rear Wall Venting Graph

Horizontal dimension from the fi nished outside wall

to the center of the pipe on the fi replace

V

ertical Dimension From the Floor of Unit to the Center of the

Horizontal V

ent Pipe

Dimensions in

Feet

Combustible – 6" (152 mm)
Noncombustible – 2" (51mm)