OM-193 267 Page 17

3-11. Selecting Input Voltage

802 314 / 802 315

!

Turn Off welding power

source, disconnect input

power, and check voltage

on input capacitors accord-

ing to Section 6-3 before

proceeding.

Check input voltage available at

site.
1

Voltage Selection View

Window

Check voltage selected in unit.

Changing selection is only neces-

sary if selected value does not

match available input voltage.
2

Relinking Board PC6

3

Mounting Screws

4

Receptacle RC8 (Connection

For 230 VAC Input Power)

5

Receptacle RC7 (Connection

For 460 VAC Input Power)

Move relinking board as needed

and connect plug PLG4 (in unit) to

RC8 or RC7 according to input

power voltage.

1

Tools Needed:

5/16 in

2

3

4

3

.

Be sure to reinstall all four screws
securing relinking board in place.

5