OM-193 267 Page 38

6-5. Voltmeter/Ammeter Help Displays

.

All directions are in reference to
the front of the unit. All circuitry

referred to is located inside the

unit.

1

Help 1 Display

Indicates a malfunction in the pri-

mary power circuit. If this display is

shown, contact a Factory Autho-

rized Service Agent.
2

Help 2 Display

Indicates a malfunction in the ther-

mal protection circuitry located on

the left side of the unit. If this display

is shown, contact a Factory Autho-

rized Service Agent.
3

Help 3 Display

Indicates the left side of the unit has

overheated. The unit has shut down

to allow the fan to cool it (see Sec-

tion 3-2). Operation will continue

when the unit has cooled.
4

Help 4 Display

Indicates a malfunction in the ther-

mal protection circuitry located on

the right side of the unit. If this dis-

play is shown, contact a Factory

Authorized Service Agent.
5

Help 5 Display

Indicates the right side of the unit

has overheated. The unit has shut

down to allow the fan to cool it (see

Section 3-2). Operation will contin-

ue when the unit has cooled.
6

Help 6 Display

Indicates that the input voltage is

too low and the unit has automati-

cally shut down. Operation will con-

tinue when the voltage is within

±

15% of the operating range. If this

display is shown, have an electri-

cian check the input voltage.
7

Help 7 Display

Indicates that the input voltage is

too high and the unit has automati-

cally shut down. Operation will con-

tinue when the voltage is within

±

15% of the operating range. If this

display is shown, have an electri-

cian check the input voltage.
8

Help 8 Display

Indicates a malfunction in the sec-

ondary power circuit of the unit. If

this display is shown, contact a

Factory Authorized Service Agent.

In addition, when the optional

ground current sensor is installed,

this display indicates weld current

in the ground conductor. When this

occurs, have an electrician check

the primary and secondary

connections.

1

A

V

2

A

V

3

A

V

HE.L P−1

HE.L P−2

HE.L P−3

4

A

V

HE.L P−4

5

A

V

HE.L P−5

6

A

V

HE.L P−6

7

A

V

HE.L P−7

8

A

V

HE.L P−8

Advertising