Section 5 − programs, 1. overview of programs – Miller Electric Invision 456MP User Manual

Page 31

Advertising
background image

OM-193 267 Page 27

SECTION 5 − PROGRAMS

.

Section 5-1 provides basic information on each of the fifteen programs in the unit’s memory. See Section 5-2 for more detailed information on each

of the programs.

.

Synergic Information: The manufacturer makes no warranties, express or implied, that welds made using the synergic parameters of this equip-
ment will meet the requirements of the application.

The synergic parameters contained in this equipment are intended only to be a general guideline. The choice and use of any synergic setting must

be tested as to its suitability for the application.

5-1. Overview of Programs

Program #

Wire Type

Wire Size

Shielding Gas

IPM: Min

IPM: Max

1

Steel

.035 in

Ar/CO

2

80

750

2

Steel

.045 in

Ar/CO

2

80

750

3

Steel

.052 in

Ar/CO

2

70

750

4

Steel

.062 in

Ar/CO

2

60

400

5

Stainless

.035 in

98Ar/2CO

2

100

750

6

Stainless

.045 in

98Ar/2CO

2

90

750

7

4043AL

.035 in

Argon

240

840

8

4043AL

.047 in

Argon

150

750

9

4043AL

.062 in

Argon

120

520

10

5356AL

.035 in

Argon

350

850

11

5356AL

.047 in

Argon

200

750

12

5356AL

.062 in

Argon

180

580

13

Nickel

.035 in

75Ar/25He

120

670

14

Nickel

.045 in

75Ar/25He

100

600

15

Silicon Bronze

.035 in

Argon

120

750

16

Metal Core

.045 in

Ar/CO

2

100

750

17

Metal Core

.052 in

Ar/CO

2

50

750

18

Metal Core

.062 in

Ar/CO

2

50

500

Advertising