OM-193 267 Page 23

4-5. Initial Display, Manual Pulse MIG Mode, MIG Mode, and Stick Mode

1

Software Program Number

When power is applied, initial dis-

play with software number appears

momentarily, and then last program

to be viewed before control was

shut down appears.
2

Manual Pulse MIG Mode

The synergic control functions as a

discrete pulsed MIG CC control in

this mode.
Select top line of display, and press

Increment or Decrement button un-

til Manual Pulse MIG is displayed.
Select Amps Peak line, and use In-

crement or Decrement button to set

peak amperage from 100−400

amps, but always at least 1 amp

more than background amperage.
Select Amps Background line, and

use Increment or Decrement button

to set background amperage (min:

10 amps; max: 300 amps, but al-

ways at least 1 amp less than peak

setting).
Select ms Pulse Width line, and use

Increment or Decrement button to

set pulse width (1 - 5 ms, but max

setting may be less depending on

Frequency setting).
Select Amps Start line, and use In-

crement or Decrement button to set

starting amperage (150 - 530 am-

peres). This amperage value is

used at the start of the weld or when

an arc is restarted.
Use Output Adjust control to set

pulse frequency. The range is 30 -

300 pulses per second, but max

setting may be less depending on

Pulse Width setting.
3

MIG Mode

The synergic control provides volt-

age control.
Select top line of display, and press

Increment or Decrement button un-

til MIG is displayed. Select Induc-

tance line, and use Increment or

Decrement button to set inductance

(0−100% in increments of one). Use

Output Adjust control to set voltage

value (10−35 volts).
4

Stick Mode

In the Stick mode, the user can se-

lect contactor control (remote or

On) and the Dig value.
Select contactor control line and

press Increment or Decrement but-

ton to select Remote contactor con-

trol or On. The contactor is On at all

times when On is selected.
Select Dig line, and and use Incre-

ment or Decrement button to set

Dig value (min: 0%; max: 100%).

Dig helps arc starting and reduces

sticking while welding. The higher

the dig value defined, the more the

short-circuit amperage increases at

low arc voltage.

I N V I S I O N

4 5 6 M P

C O P Y R I G H T

(C)

1 9 9 8

M I L L E R

E l e c t r i c

M f g

C o

X X X X X X

> P r g 1 7

M I G

3 0 %

I n d u c t a n c e

3

> P r g 1 6

M a n u a l

P u l s e

3 4 6

A m p s

P e a k

7 8

A m p s

B a c k g r o u n d

1 . 7 3

m s

P u l s e

W i d t h

3 4 6

A m p s

P e a k

7 8

A m p s

B a c k g r o u n d

1 . 7 3

m s

P u l s e

W i d t h

4 0 0

A m p s

S t a r t

2

Display scrolls to

show line 5.

1

With > on top line,

press Increment or

Decrement button until

Manual Pulse MIG ap-

pears.

With > on top line,

press Increment or

Decrement button until

MIG appears.

> P r g 1 8

S T I C K

C o n t a c t o r

R E M O T E

2 5 %

D I G

4

With > on top line,

press Increment or

Decrement button until

STICK appears.