7. choosing pulse programs and setting parameters – Miller Electric Invision 456MP User Manual

Page 29

Advertising
background image

OM-193 267 Page 25

4-7. Choosing Pulse Programs and Setting Parameters

> P r g

2

0 4 5 S t

A r / C O 2

A d a p t i v e

Setting Arc Length:
Arc length is adjusted with the Output Adjust control.

Displayed preset Trim values (0 − 100) are for reference

only.
Adjustment normally needed if wire feed speed or type of

weld joint is changed.
Set arc length that best applies to your application.

Choosing Adaptive Or Non Adaptive:
Adaptive: Pulse frequency is automatically regulated

to maintain a constant arc length, regardless of

changes in wire stickout.
Non Adaptive: Constant pulse frequency is main-

tained, regardless of the arc length.
Choose mode which best applies to your

application.

Choosing Pulse Program:
Pulse programs are pre-written and cannot be

changed by the user. See Section 5 for program

parameters and recommended gas mixtures.
Choose program depending on the type and size of

wire, and type of shielding gas used. For example,

the program shown below is for .045 steel wire using

Ar − CO

2

gas.

Advertising