EasyCoder PL4 Printer User’s Guide

Note: If you do not press the Feed button within 3
seconds, the printer prints “Dump mode not entered” and
resumes normal operation.

3

At this point, the printer is in Dump mode and prints the
ASCII hex codes of any data sent to it and their text
representation (or [.] if not a printable character).

Additionally, a file with a .DMP extension containing the ASCII
information is created and stored in the printer’s memory. You
can view, clone, or delete the file using the Intermec PLUS
application.

To exit Communications Diagnostics mode and return the printer to
normal operations

1

Turn the printer off.

2

Wait 5 seconds.

3

Turn the printer on.

Specifications

Printing Specifications

Print density

8 dots/mm (203 dots/inch)

Print width

Up to 103.8 mm (4.09 inches)

Print speed

76.2 mm (3 inches) per second

Printhead life, calculated

50 km (1,964,160 inches) nominal

Distance from print element to
top of form

14.5 mm (0.571 inch) or 116 dots

Memory/Communications Specifications

Flash memory

2 MB flash (standard)

SRAM memory

2 MB SRAM (standard)

Standard
communications

Configurable baud rate (from 9600 to 115.2 Kbps),
parity and data bits. The highest baud rate with
consistent results is 38.4 Kbps.

Software (XON/XOFF) or hardware (DTR/STR)
communication handshake protocols.