Hard Program Checks

v

For a Hard Program Check that occurs during either a power on/bring up

sequence or normal operations, do the following:
– SELECT the Save Traces pushbutton to save all existing trace data to diskette,

if desired.

– SELECT the Restart pushbutton. If the window does not reappear after the

completion of the Restart procedure, retry the operation in progress when the

Program Check condition occurred.

– If the window reappears after the completion of the Restart procedure,

SELECT

the Shutdown pushbutton.

– At the completion of the Shutdown procedure, power off the system.
– Switch power on to the system.
– At the completion of the power on sequence, retry the operation in progress

when the Program Check condition occurred.

– Call for service if the problem continues.

v

For a Master Program Check occurring during a power on/bring up sequence,

do the following:
– SELECT the Save Traces pushbutton to save trace data to diskette, if desired.
– SELECT the Continue pushbutton.
– If the window reappears, call for service.

Figure 38. Hard Program Check Window - Normal Operations