5.1 Sahalee Baseboard Management Controller

The Sahalee BMC contains a 32-bit RISC processor core and associated peripherals used to
monitor the system for critical events. The Sahalee BMC, packaged in a 156-pin BGA, monitors
all power supplies, including those generated by the external power supplies and those regulated
locally on the Server Board.

The Sahalee BMC also monitors SCSI termination voltage, fan tachometers for detecting a fan
failure, and system temperature. Temperature is measured on each of the processors and at
locations on the Server Board away from the fans. When any monitored parameter is outside the
defined thresholds, the Sahalee BMC logs an event in the System Event Log (SEL).

Management controllers and sensors communicate on the I

2

C-based Intelligent Platform

Management Bus. Attached to one of its private I

2

C bus is Hecetas, which is an ADM1026. The

ADM1026 is a versatile Systems Monitor ASIC. Some of its features include:

Analog measurement channels

Fan speed measurement channels

General-Purpose Logic I/O pins

Remote temperature measurement

On-chip temperature sensor

Chassis intrusion detection

The table below details some of the inputs on Hecetas as used in the SDS2.

Table 14. ADM1026 Input Definition

Pin

Signal Name

Description

3

N_ADM_DIS_CPU1_L

CPU1 Stop Clock

4

N_ADM_DIS_CPU2_L

CPU2 Stop Clock

5

CPU2_VID0

CPU2 VID[0]

6

CPU2_VID1

CPU2 VID[1]

9

CPU2_VID2

CPU2 VID[2]

10

CPU2_VID3

CPU2 VID[3]

11

CPU2_VID4

CPU2 VID[4]

12

CPU1_VID0

CPU1 VID[0]

2

CPU1_IERRN

CPU1 IERR

1

CPU2_IERRN

CPU2 IERR

48

CPU1_VID1

CPU1 VID[1]

47

CPU1_VID2

CPU1 VID[2]

46

CPU1_VID3

CPU1 VID[3]

45

CPU1_VID4

CPU1 VID[4]

44

N_CPU1_THERMTRIPN

CPU1 Thermal Trip

43

N_CPU2_THERMTRIPN

CPU2 Thermal Trip

16

N_FRONTOPEN+00

Chassis Intrusion

Advertising