Intel SDS2 User Manual

Page 54

Advertising
background image

BIOS

Intel® Server Board SDS2

Revision 1.2

Order Number: A85874-002

40

Sensor

Name

Sensor

#

Sensor Type

Event/

Reading

Type

Event

Offset

Triggers

Power Unit
Status

01h

Power Unit -
09h

Sensor
Specific - 6Fh

Power Off,

Power Cycle,

A/C Lost,

Power Unit
Redundancy

02h

Power Unit -
09h

Generic 0Bh

Redundancy Regain

Redundancy lost

Watchdog

03h

Watchdog2 –
23h

Sensor
Specific - 6Fh

Timer Expired,

Hard Reset,

Power Down,

Power Cycle,

Timer Interrupt

Platform
Security
Violation

04h

Platform
Security
Violation
Attempt - 06h

Sensor
Specific - 6Fh

- Secure mode
violation attempt,

- Out-of-band access
password violation

Physical
Security
Violation

05h

Physical
Security - 05h

Sensor
Specific - 6Fh

General Chassis

Intrusion,

LAN Leash Lost

POST Error

06h

System
Firmware
Progress – 0Fh

Sensor
Specific - 6Fh

POST error

FP Diag
Interrupt (NMI
for IA-32, INIT
for IA-64)

07h

Critical
Interrupt - 13h

Sensor
Specific - 6Fh

Front Panel NMI

Memory

08h

Memory – 0Ch

Sensor
Specific - 6Fh

Correctable ECC,

Uncorrectable ECC

Event
Logging
Disabled

09h

Event Logging
Disabled – 10h

Sensor
Specific - 6Fh

Correctable Memory

Error Logging

Disabled,

Log Area

Reset/Cleared

BB +1.25V

0Ah

Voltage – 02h

Threshold -
01h

-

BB +2.5V

0Bh

Voltage – 02h

Threshold -
01h

-

BB +3.3V

0Ch

Voltage – 02h

Threshold -
01h

-

BB +3.3V
Standby

0Dh

Voltage – 02h

Threshold -
01h

-

BB +5V

0Eh

Voltage – 02h

Threshold -
01h

-

BB +12V

0Fh

Voltage – 02h

Threshold -
01h

-

Advertising