Scan edges programming – Icom IC-208H User Manual

Page 57

Advertising
background image

42

7

SCAN OPERATION

7

Scan edges programming

Scan edges can be programmed in the same manner as
memory channels. Scan edges are programmed into scan
edges, 1A/1B to 5A/5B, in memory channels.

q Set the edge frequency of the desired frequency range in

VFO mode:
➥ Set the frequency using [DIAL].

➥ Set other data (e.g. repeater settings, etc.) if desired.

w Push [S.MW•MW].

• “!” indicator and channel number blink.

e Rotate [DIAL] to select one of scan edge channel, 1A, 2A,

3A, 4A or 5A.

r Push [S.MW•MW] for 1 sec. to program.

• 3 beeps sound and VFO is automatically selected.
• Scan edge 1B, 2B, 3B, 4B or 5B is automatically selected when

continuing to push [S.MW•MW] after programming.

t To program a frequency for the other pair of scan edges,

1B, 2B, 3B, 4B or 5B, repeat steps q to r.

• If the same frequency is programmed into a pair of scan edges,

programmed scan will not function.

[EXAMPLE]: Programming 145.300 MHz into scan edges 1A.

Push

Rotate for setting frequency, etc.

Rotate

Push for 1 sec. and continue to push

Beep

Beep

Beep

Beep

Advertising