Installing the processor wind tunnel – Intel SHG2 User Manual

Page 32

Advertising
background image

32

Intel Server Board SHG2 Product Guide

7. Position the retention clip over the plastic tab and engage the retention clip end-slot over the

plastic tab (see 1 in Figure 14). Note that the slot in the clip provides room for side-to-side
motion while engaging the retention clip slots located at each end.

8. Press downward on the retention clip ends over the plastic tabs on the retention bracket (see

2 in Figure 14).

9. Install two retention clips for each processor you install.

OM14368

2

2

1

Figure 14. Attaching the Heat Sink and Retention Clip

Installing the Processor Wind Tunnel

The following instructions apply to the Intel SC5200 Base Server Chassis and reference chassis
installations. If you are installing your server board in the Intel SC5200 Hot-Swap, Redundant
Power Server Chassis, DO NOT install the processor wind tunnel. The ducting in the Intel SC5200
Hot-Swap, Redundant Power Server Chassis eliminates the need for a processor wind tunnel.

Air flow for the processor wind tunnel should be directed toward the rear of the chassis as shown
below.

OM14375

Figure 15. Processor Wind Tunnel Air Flow