Server Board installation

33

1. Install processor wind tunnel center section over the heat sink / processor assembly. Note that

plastic tabs on the wind tunnel center section engage the tabs on the retention clips.

OM14369

Figure 16. Attaching the Wind Tunnel Assembly

2. Attach the processor wind tunnel fan to the wind tunnel air intake assembly as shown. The fan

label must be pointing into the air intake assembly.

OM14370

Fan label

Figure 17. Attaching the Heat Sink Fan to the Air Intake Assembly

CAUTION

To ensure proper system cooling, the heat sink fan must be installed as
shown in Figure 18 and the air intake fan assembly must be attached to the
side of the processor / wind tunnel assembly nearest to the front of the
chassis.