How You Use the FRUSDR Load Utility

This utility is compatible with ROM-DOS Ver. 6.22, MS-DOS

Ver. 6.22, and later versions. The

utility accepts CFG, SDR and FRU load files. The executable file for the utility is frusdr.exe. The
utility requires the following supporting files:
• One or more .fru files describing the system’s field replaceable units
• A .cfg file describing the system configuration
• A .sdr file describing the sensors in the system

Command Line Format

The basic command line format is

frusdr [/?] [/h] [/d {smb, fru, sdr}] [/cfg filename.cfg] /p

Command Description

frusdr

Is the name of the utility

/? or /h

Displays usage information

/d {smb, fru, sdr}

Only displays requested area

/cfg filename.cfg

Uses custom CFG file

/p

Pause between blocks of data

Parsing the Command Line

The FRUSDR Load Utility allows only one command line function at a time. A command line
function may consist of two parameters; for example, cfg filename.cfg. Any invalid parameters
result in displaying an error message and exiting the program. You can use either a slash (/) or a
minus sign (-) to specify command line options. The /p flag may be used in conjunction with any
of the other options.

Displaying Usage Information

When the utility is run with the /? or /h command line flags, the following message is displayed:

FRU & SDR Load Utility Version X.XX

Usage:

frusdr

Is the name of the utility.

/? Or /h

Displays usage information.

/d {smb,fru,sdr}

Only displays requested area.

/cfg filename.cfg

Uses custom CFG file.

/p

Pause between blocks of data.

Displaying a Given Area

When the utility is run with the /d SMB, /d FRU, or /d SDR command line flag, the indicated area
is displayed. Each area represents a sensor; one sensor for each instrumented device in the server.
If the given display function fails because of an inability to parse the data present or a hardware
failure, the utility displays an error message and exits.