5 conversion rate register, Conversion rate register, Thermal sensing device conversion rate register – Intel Itanium 2 Processor User Manual
Page 90

90
Datasheet
System Management Feature Specifications
6.7.5
Conversion Rate Register
The contents of the conversion rate register determine the nominal rate at which analog-to-digital
conversions happen when the thermal sensing device is in auto-convert mode.
shows
the mapping between conversion rate register values and the conversion rate. As indicated in
, the conversion rate register is set to its default state of 02h (0.25 Hz nominally) when
the thermal sensing device is powered-up. There is a ±25% error tolerance between the conversion
rate indicated in the conversion rate register and the actual conversion rate.
Table 6-16. Thermal Sensing Device Conversion Rate Register
Register Contents
Conversion Rate (Hz)
00h
0.0625
01h
0.125
02h
0.25
03h
0.5
04h
1
05h
2
06h
4
07h
8
08h to FFh
Reserved for future use