Datasheet

System Management Feature Specifications

6.7.5

Conversion Rate Register

The contents of the conversion rate register determine the nominal rate at which analog-to-digital
conversions happen when the thermal sensing device is in auto-convert mode.

Table 6-16

shows

the mapping between conversion rate register values and the conversion rate. As indicated in

Table 6-16

, the conversion rate register is set to its default state of 02h (0.25 Hz nominally) when

the thermal sensing device is powered-up. There is a ±25% error tolerance between the conversion
rate indicated in the conversion rate register and the actual conversion rate.

Table 6-16. Thermal Sensing Device Conversion Rate Register

Register Contents

Conversion Rate (Hz)

00h

0.0625

01h

0.125

02h

0.25

03h

0.5

04h

1

05h

2

06h

4

07h

8

08h to FFh

Reserved for future use