Image adjustment, A pg. 27), A pg.27 – JVC VN-C215V4U User Manual

Page 27: Eimage adjustmentf)

Advertising
background image

27

Alarm Input

Connect this terminal to sensor devices, such as
an infrared sensor, door sensor, metal sensor,
manual switch, etc.

Input requirements

● No-voltage relay NPN open collector input

● Polarity of input detection can be selected

using a software

● Make/Break (500 ms and above)

● Circuit current at low level: 0.3 mA

● Applied voltage at high level: 3.3 V

Alarm Output

Connect this terminal to annunciating devices,
such as annunciators, indicators, lights, buzzers,
etc.

Output requirements

● Equivalent to NPN open collector output (Set

the output put logic via the Internet Explorer)

● Allowable applied voltage: DC12 V and below

● Allowable inflow current: 50 mA

● Momentary (100 ms - 5000 ms) output

(Set time via the Internet Explorer
(

A Pg. 50))

Note

● Connect the GND cable of this camera to the

GND of the annunciating device.

When the camera is mounted, adjust the image
settings while looking at the actual image.

Mounting the test monitor

Connect the [MONITOR] terminal of the camera
to the test monitor to adjust the camera shooting
direction, field angle and focus.

T When configuring, turn on the power of the

camera.

DC3.3 V

R

3.3 V

0.3 mA

VCC

OUT

GND

GND

OUT

R

GND

(Alarm input equivalent circuit)

Input 1
or Input 2

Sensor

example (1)

Sensor

example (2)

Relay switch etc.

Camera unit

IN

R

DC 12 V

GND

GND

Example of

annunciating

devices

(Alarm output equivalent circuit)

Output 1
or Output 2

Camera unit

Image adjustment

[MONITOR]
terminal

75

K terminated

Test monitor

VN-C215_EN.book Page 27 Monday, November 27, 2006 9:46 AM

Advertising