Setting

Alarm Environment Page (continued)

Setting Using Internet
Explorer (continued)

BFTP (continued)

[Pre Post Recording Frame Rate] is constrained by the frame rate as set on
the Encoding page. (

A Pg. 44)

The actual frame rate used for transmission will be the upper limit on the
Encoding page even if a value that is larger than the frame rate in the
Encoding page is specified. The upper limits of [Pre Post Recording Before
Trigger] and [Pre Post Recording After Trigger]
are determined by settings
on the Encoding page. In addition, [Frame Rate] is in a trade-off relationship
with [Pre Post Recording Before Trigger] and [Pre Post Recording After
Trigger]
. In the case of a combination such that the input value cannot be
realized, adjustments will be automatically made on the item that is not
specified.
The name of the file to be transmitted via FTP is made up of the action
number, year, month, day, hour, minute, second, number and trigger flag.

Example: 01-20050711152904-001-0.jpg
The first 2 digits are the action number, and the following 14 digits denote
the year, month, day, hour, minute and second.
The 3 digits after the second hyphen is the number of the series of JPEG
files to be sent via that FTP. The first file is numbered

A000B. The last digit

denotes the trigger flag. This is displayed as

A1B only for the JPEG file

during a trigger input, and as

A0B if otherwise.

C

Alarm Output

For setting the alarm output.

Output
Duration

For setting the output time of [Manual Output].

Manual
Output

For operating alarm output manually.
The current output status appears on the right. When [Output Duration] is set
to

A0B, pressing the [Make] button switches the alarm to Make output, while

pressing the [Break] button switches the alarm to Break output.
When [Output Duration] is set to a value other than

A0B, pressing the [Make]

button switches the alarm to Make output only during the duration of the
output, upon which it switches to Break output.
When the output duration is set to a value other than

A0B, pressing the

[Break] button switches the alarm to Break output only during the duration of
the output, upon which it switches to Make output.