0 troubleshooting procedures, J-400 series – Jacuzzi J - 470 User Manual

Page 83

Advertising
background image

Page 77

J-400 Series

17.0 Troubleshooting Procedures
In the unlikely event your spa is not working the way you believe it
should, please first review all the installation and operating instructions in
this manual and check the message on the panel display; second, if you
are still not satisfied it is working properly, please follow the appropriate
troubleshooting instructions.

ProbleM

PrOCeDure

NONE OF THE

COMPONENTS

OPERATE (i.e.

pump light)

Check the control panel lights.

1. If there are letters or symbols displayed on

the screen, refer to the previous section to

determine the meaning and action required.

2. If nothing appears on the screen:

A. Check the household circuit breaker.

B. Contact you dealer or authorized service

center.

PUMP DOES

NOT OPERATE

AND ICON DOES

Activate the “JETS”:

1. If no sound is detected or if a “buzzing” sound

is detected, turn off power to the spa and

contact your dealer or service center.

2. If motor operates but no water flows to jets:

A. Pump may not be properly primed. See

instructions below.

B. Contact dealer or authorized service center.

Pump Priming Instructions:
1. Turn off power to the spa.
2. Remove the handle from the massage selector supplied by the pump

you are priming.

3. Loosen the massage selector’s cap slightly (counterclockwise),

listening for the air to seep out.

4. Tighten the cap finger-tight, replace the handle and turn the hot tub’s

power back on.

note: This method must be used for the jet’s pumps because these
pumps are not connected to the main filter system in any way.

CauTIOn: If freezing conditions exist and pump is not operational,

take measures to protect the system from freeze damage. See

Section titled “Winterizing” (page 70).