The interface on the port in which an SFP or SFP+ transceiver is installed in an SFP+
uplink module is down

Problem

The interface on the port in which an SFP or SFP+ transceiver is installed in an
SFP+ uplink module installed in an EX3200 or EX4200 switch is down.

When you check the status with the CLI command

show interfaces ge-

or with the

J-Web user interface, the disabled port is not listed.

Cause

By default, the SFP+ uplink module operates in the 10-gigabit mode and supports
only SFP+ transceivers. The operating mode for the module is incorrectly set.

Solution

Either SFP+ or SFP transceivers can be installed in SFP+ uplink modules. You must
configure the operating mode of the SFP+ uplink module to match the type of
transceiver you want to use. For SFP+ transceivers, configure the 10-gigabit operating
mode and for SFP transceivers, configure the 1-gigabit operating mode. See “Setting
the Mode on an SFP+ Uplink Module (CLI Procedure)” on page 168
.

Related Topics

Troubleshooting Uplink Module Installation or Replacement on EX3200 and
EX4200 Switches on page 192

Monitoring Interface Status and Traffic

Configuring Gigabit Ethernet Interfaces (CLI Procedure)

Configuring Gigabit Ethernet Interfaces (J-Web Procedure)

Removing a Transceiver from an EX Series Switch on page 177

Uplink Modules in EX3200 and EX4200 Switches on page 33

EX Series Switches Interfaces Overview

Troubleshooting Uplink Module Installation or Replacement on EX3200 and EX4200
Switches

This topic provides troubleshooting information for specific problems related to
uplink module ports on EX3200 and EX4200 switches.

1.

Virtual Chassis port (VCP) connection does not work on page 192

2.

One of the last four network ports on an EX3200 switch with an SFP or SFP+
uplink module installed is disabled on page 193

Virtual Chassis port (VCP) connection does not work

Problem

The Virtual Chassis port (VCP) connection configured in an EX4200 switch does not
work.

A port of the uplink module is set as a VCP.

192

The interface on the port in which an SFP or SFP+ transceiver is installed in an SFP+ uplink module is down

Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches

Advertising
This manual is related to the following products: