223

16.2 I/O Access Time

Figure 16-6 illustrates the I/O read and write cycles.

Figure 16-6. I/O Read and Write Cycles—No Extra Wait States

NOTE: /IOCSx can be programmed to be active low (default) or active high.

Tadr

Tadr

External I/O Read (no extra wait states)

CLK

A[15:0]

External I/O Write (no extra wait states)

CLK

A[15:0]

/IORD

valid

T1

Tw

T1

Tw

T2

valid

T2

/BUFEN

/IOCSx

/IOWR

/BUFEN

D[7:0]

valid

Tsetup

Thold

/CSx

/IOCSx

TCSx

TIOCSx

TIORD

TBUFEN

TCSx

TIOCSx

TIORD

TBUFEN

valid

D[7:0]

/CSx

TCSx

TIOCSx

TIOWR

TCSx

TIOCSx

TIOWR

TBUFEN

TBUFEN

TDHZV

TDVHZ