Siemens E-110-I User Manual

Page 86

Advertising
background image

SIEMENS ADSL E-110_E-110-I user manual

Problem

Troubleshooting Suggestion

Cannot access the Configuration

Manager program from your

browser.

Use the ping utility to check whether your PC can communicate with

the ADSL Router’s LAN IP address (by default 192.168.1.1). If it cannot,

check the Ethernet cabling.
Verify that you are using Internet Explorer v5.0 or later, or Netscape

Navigator v4.7 or later. Support for Javascript® must be enabled in

your browser. Support for Java® may also be required.
Verify that the PC’s IP address is defined as being on the same subnet
as the IP address assigned to the LAN port on the ADSL Router.

Changes to Configuration
Manager are not being retained.

Be sure to use the Commit function (Admin > Commit & Reboot) after
any changes.

Upgrading

Error Message

Possible cause

Action

invalid checksum

The firmware file to be used is
damaged or the file format is wrong.

Make sure that your firmware file format is
valid or get a new firmware file.

invalid hardcode

The firmware file is not compatible
with the model of your ADSL Router.

Download a compatible firmware from the
Web.

unknown flags type

The firmware version is not compatible. Download a compatible firmware from the

Web.

internal isfs error /
internal flashfs error

System error occurs. It may cause by
the lack of memory.

Reboot your ADSL Router and perform the
upgrade task again.

invalid file format

The firmware file format is invalid.

Check the file format is correct, otherwise
download a firmware file with correct

format.

get an error message The TFTP server responses with error

message.

Make sure the file name you enter is
correct. Otherwise the TFTP server may

response with the error message “File not

found”.

transfer time out

The transfer session is interrupted.

a. Make sure the TFTP server is on the

same subnet with the ADSL Router.

b. Make sure you the IP address of the

TFTP server you specify is correct and

that your TFTP server is started.

c. If error still occurs, reboot your ADSL

Router and perform the upgrade task

again.

firmware update in

process

The upgrade is already in process

Do not turn off your ADSL Router

otherwise you will cause damage to the

device

no remote server IP

The IP address of the TFTP server is not

specified

Specify the IP address of the TFTP server is

not specified.

can’t allocate update

buffer

It may cause by the lack of memory.

Reboot your ADSL Router and perform the

upgrade task again.