SNMP Commands

7-43

7

Command Mode

Global Configuration

Command Usage

• This command enables both authentication failure notifications and

link-up-down notifications.

• The snmp-server host command specifies the host device that will receive

SNMP notifications.

Example

Related Commands

snmp-server host (7-44)

snmp-server host

This command specifies the recipient of an SNMP notification. Use the no form to
remove the specified host.

Syntax

snmp-server host

<1 | 2 | 3 | 4> <host_ip_address | host_name>

<community-string>

no snmp-server host

1 - First SNMP host.
2 - Second SNMP host.
3 - Third SNMP host.
4 - Fourth SNMP host.
host_ip_address - IP of the host (the targeted recipient).
host_name - Name of the host. (Range: 1-63 characters)
community-string - Password-like community string sent with the

notification operation. Although you can set this string using the
snmp-server host

command by itself, we recommend that you define this

string using the snmp-server community command prior to using the
snmp-server host

command. (Maximum length: 23 characters)

Default Setting

Host Address: None
Community String: public

Command Mode

Global Configuration

Enterprise AP(config)#snmp-server enable server