SMC Networks SMC2552W-G2-17 User Manual

Page 67

Advertising
background image

System Configuration

6-20

6

When setting up VLAN IDs for each user on the RADIUS server, be sure to use the
RADIUS attributes and values as indicated in the following table.

VLAN IDs on the RADIUS server can be entered as hexadecimal digits or a string
(see “radius-server vlan-format” on page 7-63).

Note:

The specific configuration of RADIUS server software is beyond the scope of this
guide. Refer to the documentation provided with the RADIUS server software.

VLAN Classification

– Enables or disables VLAN tagging support on the access

point.

Native VLAN ID

– The VLAN ID that traffic must have to be able to manage the

access point. (Range 1-4094; Default: 1)

Number

RADIUS Attribute

Value

64

Tunnel-Type

VLAN (13)

65

Tunnel-Medium-Type

802

81 Tunnel-Private-Group-ID

VLANID

(1 to 4094 as hexadecimal or string)

Advertising