• When connecting the Wide SCSI cable, turn off all of the connecting devices,

including the AIT autoloader and the host computer.

• When connecting the AIT autoloader as the last device on the SCSI bus, be

sure to attach the provided terminator.

• In LVD (Low Voltage Differential) SCSI, make the total length of the SCSI

cable (internal and external), which connects the host computer and the device
at the end of the SCSI bus, shorter than 12 m (39.4 ft.). (The length of the AIT
autoloader internal cable is 0.5 m (19.7 in.).)

• Using SCSI cables longer than 30 cm (11.8 in.) to connect between devices is

recommended.

• SCSI cables cannot be branched.

Notes

• For information about the SCSI bus, see “SCSI Specifications” (page 46) in

the “Appendix”.

• Prepare the necessary SCSI cables. For information about SCSI cable

specifications, see “SCSI Cable and Terminator Specifications” (page 46) in
the “Appendix”.

1

Confirm that the power to the host computer and AIT autoloader are off.

2

Connect the SCSI cable and terminator as shown in the figure below.

1

Use a commercial SCSI cable to connect the AIT autoloader to the host
computer.

2

Connect the provided terminator to connector.