Sony STORSTATION LIB-D81 User Manual

Page 48

Advertising
background image

48

Appendix

22

Detected SCSI parity error.
Command phase retried but
gave up.

—

Yes

23

Detected SCSI parity error.
Data Out phase retried but
gave up.

—

Yes

24

Detected a parity error
message. Message In phase
retried but gave up.

—

Yes

25

Received Initiator detected
error message. Message
phase retried but gave up.

—

Yes

26

Received Initiator detected
error message. Command
phase retried but gave up.

—

Yes

27

Received Initiator detected
error message. Status phase
retried but gave up.

—

Yes

28

Received Initiator detected
error message. Data In phase
retried but gave up.

—

Yes

29

Received Initiator detected
error message. Data Out
phase retried but gave up.

—

Yes

2A

Received an illegal message
from the SCSI interface.

—

Yes

2B

Received an illegal Identify
message at the SCSI interface

—

Yes

2C

Failed reselection. Reselection
retried but gave up.

—

Yes

2F

REQ/ACK handshake timeout
or controller chip interruption
timeout at the SCSI interface.

—

Yes

30

Reports a unit attention event.

—

Yes

31

An as yet unsupported LUN
specified at the SCSI
interface.

—

Yes

32

Loader not yet ready.

—

Yes

33

Loader front door open.

—

Yes

34

Currently in reprogramming
mode.

—

Yes

35

Currently in menu mode.

—

Yes

36

Reported an information
exception condition.

—

Yes

41

Reception of drive data
timeout at the drive interface.

[L ] and [4 1] appear
alternately on the message
display.

Yes

42

Received data of abnormal
length from drive at the drive
interface.

[L ] and [4 2] appear
alternately on the message
display.

Yes

43

Drive detected as offline at the
drive interface.

[L ] and [4 3] appear
alternately on the message
display.

Yes

70

Detected calibration error
(lower sensor readings
abnormal).

[L ] and [7 0] appear
alternately on the message
display.

Yes

Error code Description

Display

Logged

Advertising