Use the test command to get more information, type, Fc-al controller failure, Symptom – Sun Microsystems SUN FIRE 280R User Manual

Page 220: Action

Advertising
background image

192

Sun Fire 280R Server Owner’s Guide • January 2001

2. Use the

test

command to get more information, type:

3. Take one of the following actions depending on what the

probe-scsi

command

reports:

a. If one drive does not respond to the FC-AL controller probe but the others do,

replace the unresponsive drive.

b. If only one internal disk drive is configured with the system and the

probe-scsi

test fails to show the device in the message, replace the drive.

4. If the problem is still evident after replacing the drive, replace the main logic

board.

5. If replacing both the disk drive and the main logic board does not correct the

problem, replace the associated FC-AL data cable and FC-AL backplane.

Note –

You can also use the

probe-scsi

command to look for failures on the

FC-AL loop. An

Unable to initialize error

message indicates a problem on the

loop. Proceed by disconnecting all the loop devices and then probe the loop again.
If the loop is present, then swap drives in and out first, then cables, and finally loop-
device backplanes to isolate the problem.

FC-AL Controller Failure

Symptom

A disk drive fails to boot or is not responding to commands.

Action

To check whether the main logic board FC-AL controller is defective, first test the
drive response to the

probe-scsi

command and then run OpenBoot Diagnostics.

ok test /SUNW,qlc

Advertising